PHOTOCELL ELECTRONIC CONTROL UNIT PECU-03
SPECIFICATIONS FOR MODEL: PECU-03
 
PARAMETERS
PECU-03
Type
Electromechanical
Voltage
240V +/- 10% Vac 50Hz
Switching Levels
Per customer specification (Default: 100 lux ON, 50 lux OFF)
Sensor
SI-NPN Phototransistor
Sensor Drift
Zero over 6 years
Spectral Drift
+/- 10% evening to evening
Switching Technology
Relay with Zero crossing switching
Wavelength Sensitivity
Peaked at 570nm
Load Handling
3 x 400W HID
Operation Temperature Range
-20°C to +60°C
Load Current Capacity
1000W Tungsten 1800VA Inductive Load
Switching Delay
Per customer specification (Default: 25 seconds)
Enclosure Material
UV stabillised Polycarbonate
Circuit Power Consumption
Less than 0.25 Watt
Power Loss During Load Handling
Negligible
P.E.C.U. Standard
BS 5972-80
Mechanical Connection
Twist-lock NEMA socket
Sealed Housing
IP67
Mechanical Construction
Fig. 2
Electromagnetic Interference
Designed to comply with EN50082-1 & EN55014
Test Standard:
Plastic
Electronics

ASTM.953-77 & G53-84
BS 5972., BS 5225 part 1 photocell linearity / Response
U.M.S.U.G. Approved
U.M.S.U.G. Approval code: 9400011

* Total Capitance Load < 120 μƒ
** Technical data subject to change without notice.





WIRING DIAGRAM: